All Products

View all the products
Picture of Shiftwise Run Time
Shiftwise Run Time

This module allow for the run time value of a piece of equipment (e.g. pump) to be recorded for a maximum of 3 shifts.

25.00 (CAD)
Picture of SetBitCounter
SetBitCounter

This add-on instruction counts the number of HIGH bit/s in an integer (INT) or double integer (DINT). Counter that counts anything that can become active at the same time and recounts if anything changes.

15.00 (CAD)
Picture of Sequencer
Sequencer

Ladder logic code for sequencing applications. A universal code structure that can be used for all sequences. Built in RSLogix Ver 20, so should be compatible with most programming versions.

25.00 (CAD)
Picture of SequenceProcessTemplate
SequenceProcessTemplate

The program is designed to govern any sequential order of tasks done by outputs with basic feedback from inputs.

25.00 (CAD)
Picture of SensCom
SensCom

The AOI provides a sensor signal to be treated according to its authenticity proof. The AOI is mainly developed to be used with any industrial protocol sensor/gateway/module (ex. Modbus sensor/gateway, remote IO etc), but could be used with any analog measured value.

20.00 (CAD)
Picture of Selector 8 real
Selector 8 real

This block selects between the first or the second group of real variables.

20.00 (CAD)
SCP_STEP7_V5.x
SCP Instruction for STEP 7 V5.x (S7-300 & S7-400)

This is a converted function block from the RS Logix 500 SCP instruction with added features. For STEP 7 V5.x (S7-300 & S7-400 PLCs)

50.00 (CAD)
Picture of Scantime
Scantime

Scantime function that can return scantime cycle in microseconds, milliseconds and/or seconds.

5.00 (CAD)
Picture of SCALING Analog Input
SCALING Analog Input

Analog Raw Value from Sensors Scaling to real Value

20.00 (CAD)
Picture of SCALE_AI
SCALE_AI

SCALE_AI Add on instruction converts raw value from Analog Input channel to engineering value and in addition presents several alarms based on user configuration, including Hi, HiHi, Lo and LoLo Alarms.

5.00 (CAD)
Picture of Runtime_Monitor
Runtime_Monitor

The module is used to create the runtime value for a condition.

25.00 (CAD)
Picture of Reverse String
Reverse String

The module reverses an ASCII string.

25.00 (CAD)
Signal generator block in ladder logic
Referance signal generator

Reference signal generator creating output value from preset during the time period.

25.00 (CAD)
Picture of Recipe Handler
Recipe Handler

This module allows recipes to be slected and stored in a PLC. An HMI application is included for FactoryTalk ME.

25.00 (CAD)
Picture of RandomNo_AOI
RandomNo_AOI

This module generates a random number (data type: Real) between 0 and 1.

2.00 (CAD)
Picture of RampGen
RampGen

Ramp Function Generator

20.00 (CAD)
Picture of Ramp function
Ramp function

Ramp block that generates a ramp using acceleration and deceleration values defined by user.

15.00 (CAD)
Picture of Ramp Down
Ramp Down

The module decreases a value when triggered.

25.00 (CAD)
Picture of Pump Control
Pump Control

The module provides control of a pump (or motor).

25.00 (CAD)
Picture of Pump Control
Pump Control

This module provides Automatic and Manual control of a pump or motor.

25.00 (CAD)
Picture of Pump AOI with Faceplate
Pump AOI with Faceplate

AOI with SE Faceplate for Pump or Motor start stop

25.00 (CAD)