All Products

View all the products
Picture of SetBitCounter
SetBitCounter

This add-on instruction counts the number of HIGH bit/s in an integer (INT) or double integer (DINT). Counter that counts anything that can become active at the same time and recounts if anything changes.

15.00 (CAD)
Picture of Sequencer
Sequencer

Ladder logic code for sequencing applications. A universal code structure that can be used for all sequences. Built in RSLogix Ver 20, so should be compatible with most programming versions.

25.00 (CAD)
Picture of DS2P
DS2P

Double Solenoid 2 position operation

20.00 (CAD)
Picture of ChangeOver_Block
ChangeOver_Block

Device change over if one duty and one standby device. PLCOpen XML file developed for Schneider Electric M251 PLC. And it's compatible with M241 and M262 PLCs also.

25.00 (CAD)
Picture of Stability checker
Stability checker

Determines if a value stays within a % range for an amount of time and returns TRUE when it does. Useful for applications in weighting quantities

15.00 (CAD)
Picture of Totalizer
Totalizer

This module is for Mitsubishi Fx3U and is built on GX works tools in function block diagram This totalizer will totalize the flow rate. The totalizer will auto reset at user's defined value as well user controlled reset is also given.

20.00 (CAD)
Picture of For_Do_Loop_AOI
For_Do_Loop_AOI

Works exactly like a for do loop in higher programming language but used in ladder logic

30.00 (CAD)
Picture of SCALE_AI
SCALE_AI

SCALE_AI Add on instruction converts raw value from Analog Input channel to engineering value and in addition presents several alarms based on user configuration, including Hi, HiHi, Lo and LoLo Alarms.

5.00 (CAD)
IC_MOV_2P
IC_MOV_2P

IC_MOV_2P Add On Instruction can be used for the control of 02-Poisition (Open/) motorized valve. In addition to the full control of motorized valve , this instruction generates Failure Alarms to enable device diagnostics and allow plant operators to perform maintenance if the valve is jammed or locked.

10.00 (CAD)
Picture of Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators
Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators

User-defined function block for CCW aimed at controlling hydraulic systems comprising of a single general proportional control valve and up to 4 bidirectional 4/3 on/off valves.

60.00 (CAD)
Picture of EDG_HMS v1.2
EDG_HMS v1.2

Converts Milliseconds to Hours / Min / Seconds.

2.00 (CAD)
Picture of CM_AO
CM_AO

The Analog Output AOI Control Module is used to condition an engineering unit analog output value into the proper range for analog output modules and devices. Note: Programmed followed ISA88, ISA95 and ISA106 Standard

30.00 (CAD)
Picture of CM_DO
CM_DO

Digital Output Control Module Note: Programmed followed ISA88, ISA95, and ISA106 Standard

20.00 (CAD)
Picture of CM_DI
CM_DI

The Digital Input AOI Control Module is used for general-purpose discrete inputs. Note: Programmed followed ISA88, ISA95, and ISA106 Standard

15.00 (CAD)
Picture of CM_VALVE
CM_VALVE

The Valve AOI Control Module can handle a spring return fail open, spring return fail close, or fail last valve. The valve can have one or two solenoids. It can have an open limit switch, or not. It can have a close limit switch, or not. Note: Programmed followed ISA88, ISA95, and ISA106 Standard

25.00 (CAD)
Picture of eTech_DOW_Date_AOI - ( RS/Studio5000)
eTech_DOW_Date_AOI - ( RS/Studio5000)

Studio 5000 - Rockwell Automation AOI Outputs - Julian Day, Day of Week, Is Leap Year and Current CPU Date/TIME

50.00 (CAD)
Picture of CM_AI
CM_AI

The Analog Input AOI Control Module is used to condition analog input signals into usable values for indication, control, and/or alarming by components of the PLC program or other systems (HMI, MES, etc.) Note: Programmed followed ISA88, ISA95 and ISA106 Standard

35.00 (CAD)
Picture of Spin Coater PLC Code & HMI
Spin Coater PLC Code & HMI

Spin coating is a technique used to spread uniform thin films on flat substrates by centrifugal force. Spin Coater ladder language programming and Human Machine Interface using PLC and touch panel

252.00 (CAD)
Signal generator block in ladder logic
Referance signal generator

Reference signal generator creating output value from preset during the time period.

25.00 (CAD)
Picture of Analyze_Real8_AOI
Analyze_Real8_AOI

8 input REAL value, find minimum. maximun and average. Except 0 if input value = 0, it won't be counted in sum and average

5.00 (CAD)
INT_TO_BIT
Integer to Bit

Integer Value Move to BIT status (Version Studio5000 V32.02)

10.00 (CAD)