With AOI Exchange, developers can purchase pre-built PLC & HMI modules from approved vendors in our marketplace. Save countless hours of development time on your next project.Browse Modules
This module provides comprehensive control function for a Direct On Line motor.
25.00 (CAD)
AnalogFB
This module provide analog scaling and alarming for an input with an raw value of 0-27648 (4-20 ma).
25.00 (CAD)
Pump AOI with Faceplate
AOI with SE Faceplate for Pump or Motor start stop
25.00 (CAD)
DI1_OK_ALARM
When your Digital input has an OK state and Alarm state, you need to process it before you shall use it. For example, Safety System, Lift Door, Emergency Switch, an application where input states false or low shall give an alarm.
5.00 (CAD)
Flashing On Off output
Use this control module to control output as on/off flashing output. An example may be 1s on, 2s Off flashlight. it also can be used for flashing a bit in HMI with set time durations.
5.00 (CAD)
Valve_Digital
The module provide control for an Digital Valve (Open/Close) as well as n HMI faceplate.
25.00 (CAD)
PowerFlex40 Monitor
This module monitors the status of a PowerFlex 40 Drive.
25.00 (CAD)
Limit real
This block limits an input depending on the configured high and low values and transfer the value to the output depending on the limits.
15.00 (CAD)
Selector 8 real
This block selects between the first or the second group of real variables.
20.00 (CAD)
Multiplexer 8 boolean-real
This block is a multiplexer function. When a single input is on, the corresponding single output real value will be on.
20.00 (CAD)
POSx_Valve_open_close
On/Off valve with a single output and both opened and closed. It also can be used without feedback - in that case ignore fail to open/close variable at the output.
feedback. Applies to all pneumatic on/off valves with both opened and closed position feedback.
25.00 (CAD)
Scantime
Scantime function that can return scantime cycle in microseconds, milliseconds and/or seconds.
5.00 (CAD)
Ramp function
Ramp block that generates a ramp using acceleration and deceleration values defined by user.
15.00 (CAD)
Bit to Integer
The module populates the status of bits into a integer.
10.00 (CAD)
Runtime_Monitor
The module is used to create the runtime value for a condition.
25.00 (CAD)
P_LDLG2
The module provide Lead Lag control for 2 motors.
25.00 (CAD)
Pump Control
The module provides control of a pump (or motor).
25.00 (CAD)
Recipe Handler
This module allows recipes to be slected and stored in a PLC. An HMI application is included for FactoryTalk ME.
25.00 (CAD)
RampGen
Ramp Function Generator
20.00 (CAD)
Two-position actuator control
Module for control of two-position actuator with feedback