All Products

View all the products
Picture of Spin Coater PLC Code & HMI
Spin Coater PLC Code & HMI

Spin coating is a technique used to spread uniform thin films on flat substrates by centrifugal force. Spin Coater ladder language programming and Human Machine Interface using PLC and touch panel

252.00 (CAD)
Picture of AB PV800 HMI and Siemens S7-1214 communication
AB PV800 HMI and Siemens S7-1214 communication

In this project AB HMI PV800 connect to Siemens S7-1214 PLC on MODBUS TCP/IP communication, and also this project has browser based scada (HMS EWON flexy 202 with GSM card and Viewon)

200.00 (CAD)
Picture of Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators
Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators

User-defined function block for CCW aimed at controlling hydraulic systems comprising of a single general proportional control valve and up to 4 bidirectional 4/3 on/off valves.

60.00 (CAD)
Picture of eTech_DOW_Date_AOI - ( RS/Studio5000)
eTech_DOW_Date_AOI - ( RS/Studio5000)

Studio 5000 - Rockwell Automation AOI Outputs - Julian Day, Day of Week, Is Leap Year and Current CPU Date/TIME

50.00 (CAD)
Picture of Anti Fire Fighting Sprinkle System
Anti Fire Fighting Sprinkle System

This module is for anti fire fighting sprinkle system. It consists of one pressure switch and two pumps controlled via VFD.

50.00 (CAD)
SCP_STEP7_V5.x
SCP Instruction for STEP 7 V5.x (S7-300 & S7-400)

This is a converted function block from the RS Logix 500 SCP instruction with added features. For STEP 7 V5.x (S7-300 & S7-400 PLCs)

50.00 (CAD)
Picture of PAx 2.0 HMI Simplified Lib 001
PAx 2.0 HMI Simplified Lib 001

Used to replace standard faceplates in PlantPAX 2.0

50.00 (CAD)
Picture of CM_AI
CM_AI

The Analog Input AOI Control Module is used to condition analog input signals into usable values for indication, control, and/or alarming by components of the PLC program or other systems (HMI, MES, etc.) Note: Programmed followed ISA88, ISA95 and ISA106 Standard

35.00 (CAD)
Picture of Integrator
Integrator

This function integrates anything you may need. Just set the parameters and you will have the output ready to use.

35.00 (CAD)
Picture of For_Do_Loop_AOI
For_Do_Loop_AOI

Works exactly like a for do loop in higher programming language but used in ladder logic

30.00 (CAD)
Picture of CM_AO
CM_AO

The Analog Output AOI Control Module is used to condition an engineering unit analog output value into the proper range for analog output modules and devices. Note: Programmed followed ISA88, ISA95 and ISA106 Standard

30.00 (CAD)
Product Barcode_SerialNos_Validation_IndirectAddressing
Product Barcode_SerialNos_Validation_IndirectAddressing

Indirect Addressing Concept For Scanning No.of Products to Avoid Duplicate Barcode Number when products are travelling through conveyor

30.00 (CAD)
Picture of Automated_Gate_System_v1.0
Automated_Gate_System_v1.0

This AOI can be used to automate a gate system with either one or two gates. The type of gate (sliding door or swing door) does not matter. For safety purposes, a safety scanner input is also integrated into the system.

30.00 (CAD)
Picture of Sequencer
Sequencer

Ladder logic code for sequencing applications. A universal code structure that can be used for all sequences. Built in RSLogix Ver 20, so should be compatible with most programming versions.

25.00 (CAD)
Picture of ChangeOver_Block
ChangeOver_Block

Device change over if one duty and one standby device. PLCOpen XML file developed for Schneider Electric M251 PLC. And it's compatible with M241 and M262 PLCs also.

25.00 (CAD)
Picture of CM_VALVE
CM_VALVE

The Valve AOI Control Module can handle a spring return fail open, spring return fail close, or fail last valve. The valve can have one or two solenoids. It can have an open limit switch, or not. It can have a close limit switch, or not. Note: Programmed followed ISA88, ISA95, and ISA106 Standard

25.00 (CAD)
Signal generator block in ladder logic
Referance signal generator

Reference signal generator creating output value from preset during the time period.

25.00 (CAD)
Picture of Level Maintainer (Schneider)
Level Maintainer (Schneider)

This module is Used to Maintain Water or oil between some Levels

25.00 (CAD)
Picture of CycleTime
CycleTime

count the operating time of equipment in 1 cycle from ON to OFF

25.00 (CAD)
Picture of Leak Detection
Leak Detection

The module periodically grabs data (digital and Analog) and stores the data in a buffer with timestamp.

25.00 (CAD)
Global object, faceplate and AOI
INTERLOCK_32x1

This package is a complete solution that allows fast development and configuration of interlocks, a task that normally takes a lot of time. This works with 32 inputs and comes with four faceplate's sizes suitable for all types of HMI and SCADA systems.

25.00 (CAD)