BNot16 function block
BNOT16

The BNOT16 block allows up to 16 Boolean conditions to be inverted. By using the BNOT16 block in application code the required inversion of signals is clearly shown within the Function Block Diagram (FBD).

25.00 (CAD)
Picture of DS2P
DS2P

Double Solenoid 2 position operation

20.00 (CAD)
Picture of Totalizer
Totalizer

This module is for Mitsubishi Fx3U and is built on GX works tools in function block diagram This totalizer will totalize the flow rate. The totalizer will auto reset at user's defined value as well user controlled reset is also given.

20.00 (CAD)
Picture of CM_DO
CM_DO

Digital Output Control Module Note: Programmed followed ISA88, ISA95, and ISA106 Standard

20.00 (CAD)
Picture of CountOH
CountOH

Count the operating time of equipment

20.00 (CAD)
Picture of SensCom
SensCom

The AOI provides a sensor signal to be treated according to its authenticity proof. The AOI is mainly developed to be used with any industrial protocol sensor/gateway/module (ex. Modbus sensor/gateway, remote IO etc), but could be used with any analog measured value.

20.00 (CAD)
Picture of Selector 8 real
Selector 8 real

This block selects between the first or the second group of real variables.

20.00 (CAD)
Picture of Multiplexer 8 boolean-real
Multiplexer 8 boolean-real

This block is a multiplexer function. When a single input is on, the corresponding single output real value will be on.

20.00 (CAD)
Picture of RampGen
RampGen

Ramp Function Generator

20.00 (CAD)
Picture of Analog output
Analog output

A comprehensive Analog output module providing different features.

20.00 (CAD)
Picture of Analog  Input
Analog Input

A comprehensive Analog Input module providing many features.

20.00 (CAD)
Picture of SCALING Analog Input
SCALING Analog Input

Analog Raw Value from Sensors Scaling to real Value

20.00 (CAD)
Picture of BypCntrl
BypCntrl

Bypass Control

20.00 (CAD)
FC valve AOI
TYPICAL FC VALVE

Contains a typical for digital Fail Close Valves with 1 solenoid and 2 limit switches. The valve closes if it is tripped or a command to close is set on it. Can receive manual operations like opening and closing the valve from a button(on the HMI).

19.99 (CAD)
AIM
TYPICAL ANALOG INPUT with M.O.S.

Takes the input from the analog card. Outputs a scaled value and HH/HI/LO/LL alarms. Maintenance override switch functionality.

19.99 (CAD)
Picture of SetBitCounter
SetBitCounter

This add-on instruction counts the number of HIGH bit/s in an integer (INT) or double integer (DINT). Counter that counts anything that can become active at the same time and recounts if anything changes.

15.00 (CAD)
Picture of Stability checker
Stability checker

Determines if a value stays within a % range for an amount of time and returns TRUE when it does. Useful for applications in weighting quantities

15.00 (CAD)
Picture of CM_DI
CM_DI

The Digital Input AOI Control Module is used for general-purpose discrete inputs. Note: Programmed followed ISA88, ISA95, and ISA106 Standard

15.00 (CAD)
Picture of Motor
Motor

Module for control motor in 2 directions

15.00 (CAD)
Result
TYPICAL ANALOG INPUT

Takes the input from the analog card.Outputs a scaled value and HH/HI/LO/LL alarms. Can be imported as a library and it will create all the variables automatically or can be imported as a AOI.

15.00 (CAD)
Picture of Limit real
Limit real

This block limits an input depending on the configured high and low values and transfer the value to the output depending on the limits.

15.00 (CAD)