All Products

View all the products
AIM
TYPICAL ANALOG INPUT with M.O.S.

Takes the input from the analog card. Outputs a scaled value and HH/HI/LO/LL alarms. Maintenance override switch functionality.

19.99 (CAD)
FC valve AOI
TYPICAL FC VALVE

Contains a typical for digital Fail Close Valves with 1 solenoid and 2 limit switches. The valve closes if it is tripped or a command to close is set on it. Can receive manual operations like opening and closing the valve from a button(on the HMI).

19.99 (CAD)
Picture of BypCntrl
BypCntrl

Bypass Control

20.00 (CAD)
Picture of SCALING Analog Input
SCALING Analog Input

Analog Raw Value from Sensors Scaling to real Value

20.00 (CAD)
Picture of Analog  Input
Analog Input

A comprehensive Analog Input module providing many features.

20.00 (CAD)
Picture of Analog output
Analog output

A comprehensive Analog output module providing different features.

20.00 (CAD)
Picture of RampGen
RampGen

Ramp Function Generator

20.00 (CAD)
Picture of Multiplexer 8 boolean-real
Multiplexer 8 boolean-real

This block is a multiplexer function. When a single input is on, the corresponding single output real value will be on.

20.00 (CAD)
Picture of Selector 8 real
Selector 8 real

This block selects between the first or the second group of real variables.

20.00 (CAD)
Picture of SensCom
SensCom

The AOI provides a sensor signal to be treated according to its authenticity proof. The AOI is mainly developed to be used with any industrial protocol sensor/gateway/module (ex. Modbus sensor/gateway, remote IO etc), but could be used with any analog measured value.

20.00 (CAD)
Picture of CountOH
CountOH

Count the operating time of equipment

20.00 (CAD)
Picture of CM_DO
CM_DO

Digital Output Control Module Note: Programmed followed ISA88, ISA95, and ISA106 Standard

20.00 (CAD)